Ehdotuksen tiedot
Tunnus:prEN 3475-605
Julkaisija:CEN
Komitea:ASD-STAN
Komitean nimi:Aerospace
Lausuntokierros alkanut:2024-10-20
Lausuntopyynnön määräaika:2024-12-19
Toimialayhteisö:SFS Suomen Standardit
Vastuuhenkilö:sirpa.sipola(at)sfs.fi
Ehdotuksen soveltamisala:
This document specifies a method for appraising the behaviour of cable insulation subjected to an electric arc initiated and maintained by a contaminating fluid.
This document is intended to be used together with EN 3475-100.
The primary aim of this test is:
- to produce, in a controlled fashion, continuous failure effects, which are representative of those, which can occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination such that electrical arcing occurs between cables; and
- to examine the aptitude of the insulation to track, to propagate electric arc to the electrical origin.
Originally defined for 115 VAC network, this test also proposes conditions for 230 VAC network. However, for 230 VAC test condition only, the test EN 3475-605 can overrule and be applied as test governance as it has been demonstrated that test EN 3475-605 is more stringent, repeatable and reproductible compared to EN 3475-604 and EN 3475-603.
Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 8). It is agreed that larger sizes need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances.
Unless otherwise specified in the technical/product standard, sizes 002, 006 and 020 cable are assessed.
Rekisteröidyttyäsi Lausuntopyyntöpalvelun käyttäjäksi voit lukea standardiehdotuksia ja kommentoida niiden sisältöä.
Kun haluat kommentoida lukemaasi tekstiä, valitse Lue ehdotus ja anna muutosehdotuksesi kohdassa Jätä kommentti.
Voit myös kertoa mielipiteesi standardiehdotuksesta kokonaisuutena. Ota kantaa siihen, hyväksytkö standardiehdotuksen vahvistamisen standardiksi.