Öljy- ja biopolttoaineala

Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: ISO/TC 193/SC 3 (Upstream area)
Alkuperä: ISO
Määräpäivä: 2018-01-24
LaajennaSupista
 
This International Standard specifies a method for the determination of hydrogen sulfide content in working field natural gas of upstream area by laser absorption spectroscopy. The analytic range is 10×10-6 to 20% (mol/mol). The analytic range can be expanded to higher content with special requirement to the instrument. The use of this international standard can involve hazardous material, operations and equipments. This international standard does not aim to address all of the safety problems associated with its use. It is the responsibility of the user of this international standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 19 (Gaseous and liquid fuels, lubricants and related products of petroleum, synthetic and biological origin.)
Alkuperä: CEN
Määräpäivä: 2018-01-25
LaajennaSupista
 
This European Standard specifies requirements and test methods for marketed and delivered automotive liquefied petroleum gas (LPG). It is applicable to automotive LPG for use in LPG engine vehicles designed to run on automotive LPG.NOTE For the purposes of this European Standard, the terms “% (m/m)” and “% (V/V)” are used to represent respectively the mass fraction, µ, and the volume fraction, f.WARNING — Attention is drawn to the risk of fire and explosion when handling LPG and to the hazard to health arising through inhalation of excessive amounts of LPG.LPG is a highly volatile hydrocarbon liquid which is normally stored under pressure. If the pressure is released large volumes of gas will be produced which form flammable mixtures with air over the range of approximately 2 % (V/V) to 10 % (V/V). This European Standard involves the sampling, handling and testing of LPG. Naked flames, unprotected electrical equipment electrostatic hazards etc. are sources of ignition for LPG.LPG in liquid form can cause cold burns to the skin. The national health and safety regulations apply.LPG is heavier than air and accumulates in cavities. There is a danger of suffocation when inhaling high concentrations of LPG.One of the tests described in this European Standard involves the operator inhaling a mixture of air and LPG vapour. Particular attention is drawn to the cautionary statement provided in A.1, where this method is referred to.
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: ISO/TC 28 (Petroleum and related products, fuels and lubricants from natural or synthetic sources)
Alkuperä: ISO
Määräpäivä: 2018-01-25
LaajennaSupista
 
This document specifies a method by which the fire hazards of pressurised sprays of fire-resistant fluids can be compared. Two sizes of propane flame are used to ignite and stabilise combustion of an air-atomised release of fluid. Measurements related to the rate of heat release, length of flame and density of smoke give quantitative information on the fire behaviour of the fluid.
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 237 (Gas meters)
Alkuperä: CEN
Määräpäivä: 2018-02-01
LaajennaSupista
 
To revise the Annex ZA, and the associated body text only, of EN 12405-1 to ensure the alignment with the Directive 2014/32/EU.
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 12 (Materials, equipment and offshore structures for petroleum, petrochemical and natural gas industries)
Alkuperä: CEN
Määräpäivä: 2018-02-05
LaajennaSupista
 
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 180 (Decentralized gas heating)
Alkuperä: CEN
Määräpäivä: 2018-02-08
LaajennaSupista
 
This European Standard specifies the requirements and test methods for the construction, safety, rational use of energy, classification and marking of non-domestic gas-fired overhead luminous radiant heaters for environmental comfort, referred to in the body of the text as "appliances".This European Standard is applicable to Type A1 and Type A3 appliances only (see 4.2.2) intended for use in other than residential dwellings:a) low gas pressure appliances operating at pressures up to and including 50 mbar;b) medium gas pressure appliances operating at pressures above 50 mbar and up to 2 bar.This European Standard is not applicable to:- appliances designed for use in domestic dwellings;- outdoor appliances;- appliances of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference gas);This standard is applicable to appliances which are intended to be type tested.
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 180 (Decentralized gas heating)
Alkuperä: CEN
Määräpäivä: 2018-02-15
LaajennaSupista
 
This document specifies the requirements and test methods for the construction, safety, classification, marking and efficiency of non-domestic gas-fired overhead radiant strips heaters and multi-burner continuous radiant tube heater systems (referred to in the body of the text as the “system”) with each burner unit under the control of an automatic burner control system.For radiant strip heaters incorporating a single burner, this standard is applicable to Type B22, B23, B52, B53, C12, C13, C32, C33 C52 and C53 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.For multi-burner continuous radiant tube heater systems this standard is applicable to type B22, B52, and C52 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.This standard also includes appliances incorporating a secondary heat exchanger in the flue system.This standard is not applicable to:a) appliances designed for use in domestic dwelling;b) outdoor appliances;c) radiant strip heaters where the heat input is in excess of 300 KW (based on the net calorific value of the appropriate reference test gas);d) continuous radiant tube heater systems where the heat input of any individual burner unit is in excess of 70 kW (based on the net calorific value of the appropriate reference test gas); e) appliances having combustion products evacuation ducts that are non-metallic in the flue system – except ducts downstream of a possible additional condensing exhaust gas heat exchanger.In addition, for heater systems incorporating multiple tube heaters this standard is not applicable to: f) appliances that are designed for continuous condensation within the flue system under normal operating conditions – except downstream a possible additional exhaust gas heat exchanger.This standard is applicable to appliances which are intended to be type tested.
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 286 (Liquefied petroleum gas equipment and accessories)
Alkuperä: CEN
Määräpäivä: 2018-02-15
LaajennaSupista
 
This European Standard defines the competence profiles, and establishes procedures for assessing the competence of persons who carry out the installation, repairing and maintaining of LPG systems in workshops covered in EN 16652-1.The requirements of this standard do not apply to "Car manufacturer network repairers" (see 3.9) when performing the activities of repairing, servicing and maintenance of vehicles from manufacturers for which they are authorized and duly trained.
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 12 (Materials, equipment and offshore structures for petroleum, petrochemical and natural gas industries)
Alkuperä: CEN
Määräpäivä: 2018-02-16
LaajennaSupista
 
This document specifies requirements and gives recommendations on integrity management of pipeline during the design, construction, commission, operation, maintenance and abandonment. It applies to offshore pipeline for transporting petroleum and natural gas.This document applies to rigid pipelines. It is not applicable for flexible pipelines, dynamic risers or those constructed from other materials, such as glass-reinforced plastics. An offshore pipeline system extends to? The first valve, flange or connection above water on platform or subsea mechanical connector with dynamic riser.? The connection point to the offshore installation (i.e. piping manifolds are not included).? The first valve, flange, connection or isolation joint at a landfall unless otherwise specified by the onshore legislation.The components mentioned above (valve, flange, connection, isolation joint) include also any pup pieces, i.e. the offshore pipeline system extends to the weld beyond the pup piece.Offshore pipelines are defined as pipelines that use universally recognized offshore pipeline construction techniques.
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 265 (Metallic tanks for the storage of liquids)
Alkuperä: CEN
Määräpäivä: 2018-02-22
LaajennaSupista
 
This document specifies the requirements for the materials, design, fabrication, erection, testing and inspection of site built, vertical, cylindrical, flat bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperatures and above, and the technical agreements that need to be reached (see Annex A).This document does not apply to tanks where the product is refrigerated to maintain it as a liquid at atmospheric pressure (see EN 14620 part 1 to 5).This document is concerned with the structural integrity of the basic tank structure and does not provide requirements for considering process design, operational issues, safety and firefighting facilities, in-service inspection, maintenance or repair. These aspects are covered in detail in other Codes of Practice (see Annex B).This document applies to closed-top tanks, with and without internal floating roofs (see Annex C) and open-top tanks, with and without floating roofs (see Annexes D and E). It does not apply to 'lift-type' gas holders.This document applies to storage tanks with the following characteristics:a) design pressure less than 60 mbar and design internal negative pressure not lower than 6,0 mbar (see 5.1 for pressure limitations);b) design metal temperature not lower than -40 °C and not higher than +300 °C (see 5.2.2);c) maximum design liquid level not higher than the top of the cylindrical shell.The limits of application of this document terminate at the following locations:- face of the first flange in a bolted flange connection;- first threaded joint on the pipe or coupling outside of the tank shell, roof or bottom; and- first circumferential joint in a pipe not having a flange connection.This document is applicable to storage tanks where, irrespective of the material strength used, the maximum allowable stress does not exceed 260 N/mm2.In addition to the definitive requirements, this document also states that the items detailed in Annex A have to be documented. For compliance with this document, both the definitive requirements and those required in Clause 4 are meant to be satisfied.
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 286 (Liquefied petroleum gas equipment and accessories)
Alkuperä: CEN
Määräpäivä: 2018-03-08
LaajennaSupista
 
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 286 (Liquefied petroleum gas equipment and accessories)
Alkuperä: CEN
Määräpäivä: 2018-03-12
LaajennaSupista
 
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: CEN/TC 12 (Materials, equipment and offshore structures for petroleum, petrochemical and natural gas industries)
Alkuperä: CEN
Määräpäivä: 2018-03-15
LaajennaSupista
 
Toimialayhteisö: Öljy- ja biopolttoaineala
Komitea: ISO/TC 67/SC 7 (Offshore structures)
Alkuperä: ISO
Määräpäivä: 2018-03-16
LaajennaSupista